• Fritsch GmbH Mahlen und Messen | Probenaufbereitung und Partikelmessung

    • Productos
    • Soluciones
    • Enciclopedia
    • Servicio técnico
    • Actualidad
    • Quiénes somos
    • Contacto
    • Inicio
    • Contacto
    • Imprimir
    • erp
    • English USA
    • English UK
    • Deutsch
    • French
    • Russian
    • IT
    • ES
    • Chinese
    • Japanese
    • Medición de tamaño de partículas
    • ·
    • Productos
    • ·
    • Dispersión de luz dinámica
    • ·
    • Instrumento de medición de nanopartículas ANALYSETTE 12 DynaSizer
    • ·
    • Description
      • Dispersión de luz estática
      • Dispersión de luz dinámica
        • Instrumento de medición de nanopartículas ANALYSETTE 12 DynaSizer
          • Software
      • Análisis gráfico dinámico

      Particle Sizers

      FRITSCH Product Manager Particle Sizers
      Dr. Günther Crolly

      Phone: 0049 67 84 70 138

      Mobile: 0049 151 14 27 27 14

      crolly(at)fritsch.de

      • Nano Particle Sizer ANALYSETTE 12 DynaSizer

      • Order number:12.3000.00 + 12.4000.00
        Price:Request quote
      • Description
      • Technical data
      • Models
      • Download

      The typical areas of application

      The ANALYSETTE 12 is perfectly suited for particle size determinations down into the lower nanometer range: with exact and reproducible results in research, development and quality control. Ideal for pigments like for example ink or chemicals, food (for example milk), pharmaceuticals, cosmetics and samples from the areas of environment and petrochemistry (for example motor oil).

      The principle

      The ANALYSETTE 12 DynaSizer utilises the thermal motions of particles in a suspension (Brownian Motion) to determine their size. Here the sample suspension is irradiated by a laser and the light scattered in a certain direction detected with high time resolution.

      From the fluctuation of the intensity of the scattered light, the movability of the particles can be calculated and then again via the Stokes-Einstein formula, their size can be calculated.

      The technology

      The design of the DynaSizer abstains completely from the usual cuvettes. The sample suspension is applied directly on a glass surface from where a laser with adjustable intensity irradiated vertically through it from below. From above, then a second glass surface is set on the suspension and clearly sets the measurement volume.

      The in a backward-direction scattered light is captured below a fixed angle with a powerful detector and the intensity fluctuation via a so called correlator processed (Autocorrelation). The obtained autocorrelation function describes how fast or slow the intensity changes. Small particles deliver a fast variation whereas for large particles this is accordingly slower.

      The ultra-thin layer technology

      The cuvette-free design enables a specific adjustment of the analysis layer thickness for the optimal adaptation to the respective conditions. For example, for measurements with high particle concentrations or in dark media, the upper limit of the measurement volume can be lowered with one simple motion and so the thickness of the analysis layer is reduced from approximately 2 mm down to 100 µm. This elegant option for reduction the measurement volume prevents problems due to multiple-scattering as well as local heating and guarantees reliable measurements of even dark media or high particle concentrations. Just as simple a thick analysis layer can be set again which then allows the measurement of suspensions with lowest particle concentrations.

      The stable measurement temperature

      Essential for particle size determinations with dynamic light scattering is the temperature control of the sample material. The ultra-thin layer technology enables - due to the 90° prism - thin, expanded analysis layers and an excellent coupling of sample material and measurement cell. So in minimal time the desired sample temperature is reached and via the Peltier elements maintained at the configurable temperatures between 15 °C und 70 °C.

      The innovative measurement design

      Due to the well-conceived design of the measurement system with 90° prism, the ANALYSETTE 12 DynaSizer is able to process the smallest sample quantities, is fast and easy to clean and makes it unnecessary to use cuvettes or other consumables. The optical design is reduced to a minimum and keeps the distance between measuring cell and detector small. The advantage: a hidh signal-to-noise ratio, which is a key factor for high measurement precision and for the detection of low particle concentrations.

      The variable laser power

      The electronic regulation of the laser power permits adaptation to broad ranges in terms of particle size and concentration. The temperature-stabilised and fibre-couple diode laser in pigtail design offers a long service life, enormous stability in the output power, ultra-stable polarisation and an optimised signal-to-noise ratio.

      Two detectors selectable

      The Nano Particle Sizer ANALYSETTE 12 is offered with two different detector systems. The ANALYSETTE 12 DynaSizer includs a high-performance Photo-Multiplier with a high amplification factor < 105, short response time < 10 ns and a very low dark current signal of approx. 150 cps - the standard model for the majority of measuring tasks.

      The ANALYSETTE 12 DynaSizer plus is suitable for particle concentrations of a few ppm and particle diameters of < 10 nm. Equipped is the DynaSizer plus with a Single Photon Avalanche Diode (SPAD) thermally stabilised with Peltier elements and has due to active quenching low dead times of below 0.1 ns and a dark count rate in the area of 10 cps.

      The comprehensive analysis

      The ANALYSETTE 12 DynaSizer embodies know-how and innovation - for instance in the powerful Padé-Laplace algorithm that interprets the measuring data correctly even in the event of multimodal particle size distributions. Of course, even conventional methods such as Cumulant or Contin can also be used. Details about the software nanoQ here.

      The features

      • Measuring range from 1 nm to 6000 nm
      • Measurement of concentrations between 0.0003 up to 40 Vol.-%
      • Direct sample application without cuvettes
      • Intelligent evaluation with high-performance Padé-Laplace algorithm
      • Measurement of the real particle size distribution
      • User-friendly operation
      • Simple simulation of measuring data

      The equipment

      The Nano Particle Sizer ANALYSETTE 12 DynaSizer is equipped with an USB-interface and the purchase  includes the software nanoQ. The software nanoQ contains besides the common methods such as Cumulant and Contain also the powerful Padé-Laplace algorithm, the multi-acquisition mode and a simulation module.

      A computer with already installed software as well as a colour ink jet printer or laser printer for outputting the measuring reports can be ordered as accessories. 

    • Enlaces directos
    • Login
    • Contacto
    • CGV
    • Información legal
    • Recomendar página
    • Imprimir
    • Preparación de muestras
    • Medición de partículas
      • Servicio / soluciones

         

         

        Servicio técnico

        Asesoramiento de aplicaciones técnicas

        Soporte técnico

        Módulo de mantenimiento remoto

        Análisis de muestras gratuito

        Descargas

        Garantía en línea

        Certificados de calidad

         

        Soluciones

        Preparación de muestras

        Dispersión

        Muestras difíciles

        Ejemplos de aplicación

        Informes de medición

        Enciclopedia

        Introducción a la medición de partículas

         

      • Productos para la medición de partículas

         

        Difracción láser

        Intervalo de medición 0,08 – 2000 µm

        Unidad de medición

        Dispersión en mojado

        Dispersión en seco

        Pozo de caída

        Dispersión en mojado de pequeñas cantidades

        Software

         

        Intervalo de medición 0,01 – 2000 µm

        Unidad de medición

        Dispersión en mojado

        Dispersión en seco

        Pozo de caída

        Dispersión en mojado de pequeñas cantidades

        Software

         

        Dispersión de luz dinámica DLS:

        Intervalo de medición 1 nm – 6 µm

      • Contacto / noticias

         

         

        Contacto

        Asesoramiento de aplicaciones

        Soporte técnico

        Módulo de mantenimiento remoto

        Contacto en todo el mundo

         

        Actualidad

        Noticias

        Roadshows

        Workshops

        Ferias

      • Enlaces

         

         

        Otras dominios

        www.fritsch-sizing.com

        www.fritsch-sizing.de

        www.fritsch-sizing.fr

        www.fritsch-sizing.ru

        www.fritsch-sizing.it

        www.fritsch-sizing.com.sg

        www.fritsch-sizing.cn

        www.fritsch-sizing.jp

        www.fritsch-sizing.co.kr

         

        www.fritsch-milling.com

      • Para visitantes ya registrados

        Introduzca su dirección de correo electrónico y contraseña:

        ¿Ha olvidado su contraseña?

      • Please complete the form below for your account: